LipoFluor-MR™ is a cell-permeant stain for mitochondria. This tracing reagent can be used on live cells, frozen and fixed tissue samples and is compatible with other dyes.
Staining of mitochondria in cardiomyocytes (top) and HeLa cells (bottom) with TR-602-Mito tracing reagent.
LipoFluor-MR™ is a cell-permeant stain for mitochondria. This tracing reagent can be used on live cells, frozen and fixed tissue samples and is compatible with other dyes. LipoFluor-MR™ has a large Stokes Shift, shows excellent resistance to photobleaching and demonstrates low cytotoxicity.
Mitochondria
Human
Fluorescent imaging of mitochondria. Cell penetration and localisation of LipoFluor-MR™ has been confirmed in prostate cells (PNT2 and 22RV1), cardiomyocytes (H9c2) and cancer cell lines (HeLa). Mitochondrial localisation has been shown in live tissues, including live adipose tissue (sheep) and muscle tissue (sheep cardiac and skeletal) and frozen or PFA fixed muscle tissue (sheep skeletal).
All Mammals, Human, Mouse
ICC, IF
Fluorescent imaging of mitochondria. Sample types: live cells, tisue (frozen and 4% paraformaldehyde). Quenching endogenous fluorescence can assist in imaging, refer to the product manual. Not suitable for application on fixed cells. Microscopy: Epifluorescence microscopy: YES; Confocal microscopy: YES; Multiphoton imaging: YES; Infrared spectroscopy: NO; Raman spectroscopy: NO; Visualization: Ex/Em: 405 nm / 600 nm.
405 nm / 600 nm.
Fluorescence
Cells, Tissues (live or fixed)
DMSO
Liquid, ready to dilute
Thin layer chromatography using alumina plates and a solvent system of ethanol and water (3:1) revealed the presence of fluorescent isomers. No amount of starting material was detected.
LipoFluor-MR™
For research use only.
United States
If protected from light, the liquid 10 mM stock solution vials are stable for 12 months from date of receipt, at 2-8°C. A vial should be diluted immediately prior to use and should be used within 24 hours for best results.
The liquid stock solution vials can be stored up to 12 months from date of receipt at 2-8°C, properly sealed and protected from light. Working solutions should be used within 24 hours and not stored for later use.
Four 0.5 mL microfuge vials containing 5.5 uL/vial of 20 mM stock solution of Lipofluor™ TR-602-Mito in DMSO. 100.8 μg per vial.
Bulk Order LipoFluor-MR™ Mitochondria Tracing Reagent
Refund Policy
Satisfaction Guaranteed
We stand by our products and are here to ensure that you get the most out of each experiment using our products and reagents.
We produce everything that we sell and are dedicated to creating reliable and high-quality products that further scientific research. All of our products are produced and quality control tested in-house. We will never sell a product unless we can get it to work in our hands. If a product does not perform as expected, please contact us within 12 months of product purchase and we will provide expert troubleshooting tips to support you. If we cannot resolve the issue, we will replace the product at no cost or offer a 100% refund. We are passionate about providing researchers with the highest quality products on the market, reagents you can count on to make your next discovery.